Technology · Rockwell Automation

Rockwell PLC programming.
Studio 5000, ControlLogix and CompactLogix.

DAXP Automation programs Rockwell Automation Allen-Bradley PLCs in Studio 5000 Logix Designer: ControlLogix and CompactLogix, FactoryTalk View and PanelView HMIs, EtherNet/IP networks and integration with Siemens equipment and robots in the same plant.

01 · WHAT WE PROGRAM

What we do with Rockwell

Logix programs that are tidy, reusable and easy to maintain.

Tasks, programs and routines with a clear structure, tags with names that make sense and repetitive logic wrapped in Add-On Instructions.

Let's talk about your project

Capabilities

ControlLogix and CompactLogix

Programming in Ladder, Structured Text, FBD and SFC. Add-On Instructions (AOI) and UDTs for reusable code.

MicroLogix and installed base

Maintenance and modification of MicroLogix and Rockwell equipment already in service.

FactoryTalk View HMI

FactoryTalk View ME and SE applications for PanelView Plus: alarms, recipes and operator-focused screens.

EtherNet/IP and DeviceNet

EtherNet/IP network configuration, drives, remote I/O and existing DeviceNet networks.

Multi-brand integration

Data exchange with Siemens PLCs, Fanuc, ABB or KUKA robots and SCADA systems via EtherNet/IP, gateways or OPC UA.

Simulation

Logic testing with Studio 5000 Logix Emulate before commissioning.

Alarms and diagnostics

Alarms generated from the logic or with Logix alarm instructions, shown in FactoryTalk View with cause, location and action.

Version management

Project comparison with the Logix Designer Compare Tool and a change list with every delivery.

We organise the project by unit: one routine per station, common operating modes and built-in diagnostics, so any technician can find what they need in the Controller Organizer without reading the whole program.

If the plant already has its own standard, such as a corporate Add-On Instruction library, we work within it instead of introducing a new one.

02 · MIGRATION

PLC-5 and SLC 500 migration

Both platforms are discontinued: every year there are fewer spares and fewer people who know them.

Moving to ControlLogix or CompactLogix takes that risk away from a machine that works and that nobody wants to touch.

Let's talk about your project

How we do it

  • 01
    Inventory

    Existing program, I/O, networks (DH+, DH-485, RIO) and HMI. Verified backup.

  • 02
    Conversion and review

    Program conversion and manual review of what does not translate cleanly: file-based addressing (N7, B3, T4…), obsolete instructions and indirect addressing.

  • 03
    Offline testing

    Critical sequences validated in emulation before the shutdown.

  • 04
    On-site switchover

    Replacement during the agreed window, with a rollback plan.

  • 05
    Documentation

    Commented program, tag list and final backup for maintenance.

Rockwell has discontinued the PLC-5 and SLC 500 families and provides conversion tools towards Logix. Those tools help, but the result still needs a review by someone who knows both platforms well.

When the available shutdown is very short, the migration can be phased: first the controller, keeping the existing I/O through adapters, and then the I/O in later shutdowns.

Application examples

Typical Rockwell projects

Illustrative examples of the kind of project we work on. They are not customer references.

Assembly line with robot stations

ControlLogix as master, robots over EtherNet/IP and model recipes from a PanelView Plus.

SLC 500 replacement

Migration to CompactLogix, program conversion and a new FactoryTalk View HMI.

Mixed Siemens + Rockwell plant

Data exchange between lines of different generations and a single SCADA to supervise them.

FAQ

Frequently asked questions

What is the difference between Studio 5000 and RSLogix 5000?

It is the same tool: from version 21, RSLogix 5000 was renamed Studio 5000 Logix Designer. Older hardware (PLC-5, SLC 500, MicroLogix) is programmed with RSLogix 5 and RSLogix 500.

Can you work in a plant that mixes Siemens and Rockwell?

Yes. It is common in plants with lines from different eras, and knowing both platforms is exactly what allows us to integrate them without bias towards either.

Is it worth migrating an SLC 500 that still works?

If the machine is critical and spares are scarce, yes: a planned migration costs far less than a long shutdown waiting for a discontinued module.

Do you modify Rockwell programs written by others?

Yes. We take a backup, understand the existing logic and document every change.

Which Studio 5000 version do you use?

The one that matches the controller firmware: in Logix, the software major revision must match the firmware. We work with the version installed on site unless an upgrade is agreed.

What if we do not have the original program with comments?

The program can be uploaded from the controller, but in PLC-5 and SLC 500 the comments and descriptions only live in the original file. When it is missing, part of the job is rebuilding that documentation.

Can a Rockwell PLC be connected to a SCADA from another vendor?

Yes. Ignition or WinCC Unified communicate with ControlLogix and CompactLogix over EtherNet/IP, and OPC UA is also possible through an intermediate server or, on recent controllers, the built-in one.

Next step

Got a Rockwell project?

Tell us what hardware it is, which version it runs and what you need to change.